XS ReVio Portable Multimeter with 201 T Electrode, 2301 T Conductivity Cell, polarographic DO Sensor and Accessories

XS ReVio Portable Multimeter with 201 T Electrode, 2301 T Conductivity Cell, polarographic DO Sensor and Accessories

R36,313.37

Measuring range:

  • pH: -2.000 ... 20.000 (0.001 pH)
  • mV: –2000… + 2000 (0.1 mV)
  • ISE: 0.001 ... 19999 ppm
  • Cond: 0.0 µS ... 1000 mS (0.1 µS - automatic)
  • Resistivity: 1 Ohm ... 10 MOhm
  • Salinity: 0.1 ppm ... 100 ppt
  • TDS: 0.1 mg / l ... 500.0 g / l
  • DO: 0.0 ... 50 mg / l (0.01 / 0.1 mg / l)
  • Saturation: 0.0… 400% (0.1 / 1%)
  • Barometric pressure: 0… 1100 mbar (1 mbar)
  • Temperature: -30 ... 130.0 ° C (0.1 ° C)

Complete with pH electrode 201 T, conductivity cell 2301T and polarographic sensor, with built-in temperature sensor and fixed cable 3m, in carrying case.

Availability:On Request
SKU
IBOR50110912

SENSORS: XS REVIO is equipped with 3 pairs of BNC - RCA (temperature) inputs. This makes it suitable for most sensors on the market. Using XS Sensor electrodes, maximum accuracy and reliability are achieved. It is supplied with XS sensors, with an integrated T sensor 3-meter cable: pH electrode 201T DHS, Conductivity cell 2301T (C = 1), Polarographic oxygen sensor

SMART CALIBRATION: Guided automatic calibration with recognition of standards, or values chosen by the user. At the end of each calibration, the graph (pH) and the calibration data are displayed. The calibrated points are always shown on the display.

GLP - GOOD LABORATORY PRACTICE: Work safely and according to GLP standards by setting the calibration expiry date and the 4-digit password, which protects calibrations, settings, and sensitive data. Using the XS DHS digital sensors, the serial number and model of the electrode can also be traced.

DATA RECORDING: 10,000 data internal memory, or direct recording on PC. The free DataLink + software allows the download of the saved data, the export In Excel and PDF format, as well as the practical graphic and table display. Micro USB connection port.

ON THE FIELD: The IP67 carrying case, impact resistant and with a pressure adapter, turns into a real mobile laboratory, complete with all accessories needed for measurement.


TECHNICAL SPECIFICATIONS

REGULATIONS
Regulations CE

PERFORMANCE
Accuracy (Cond) ± 1 % f.s.
Accuracy (pH) ± 0.002
Accuracy (Resistivity) ± 1 % f.s.
Accuracy (Salinity) ± 1 % f.s.
Accuracy (TDS) ± 1 % f.s.
Accuracy (Temperature) ± 0.2 °C
Barometric pressure accuracy ± 0.5 %
Barometric pressure measuring range (max.; min.) 1100 mbar; 300 mbar
Barometric pressure resolution 1 mbar
Cond measuring range (max.; min.) 1000 mS; 0.01 μS
Cond resolution 0.01 / 0.1 / 1 μS/cm (automatic scale)
Dissolved Oxygen measuring range (max.; min.) 50.0 mg/l; 0.00 mg/l
DO Accuracy 1.5 % f.s.
DO resolution 0.01 mg/l
ISE accuracy 0.5 % f.s. / 1 % f.s.
ISE measuring range (max.; min.) 19999 ppm; 0.001 ppm
ISE resolution 0.001 / 0.1 (automatic scale)
O2 saturation accuracy ± 10 %
O2 saturation measuring range (max.; min.) 400 %; 0.0 %
O2 saturation resolution 0.1 %
ORP measuring range (max.; min.) + 2000; - 2000
ORP resolution 0.1 / 1
Parameters pH. ORP. ISE. EC. TDS. Salinity. Resistivity. DO. Temperature
pH measuring range (max.; min.) + 20.00; - 2.00
pH resolution 0.1 / 0.01 / 0.001
Reference temperature (max.; min.) + 30 °C; + 15 °C
Resistivity measuring range (max.; min.) 10.00 MOhm*cm; 1.00 Ohm*cm
Salinity compensation Yes
Salinity measuring range (max.; min.) 100 ppt; 0.01 ppt
TDS Factor 0.40...1.00
TDS Factor (max.; min.) 1.00; 0.40
TDS measuring range (max.; min.) 500 g/l; 0.1 mg/l
Temperature coefficient (max.; min.) 10.00 % / °C; 0.00 % / °C
Temperature compensation 0.0...100.0 °C
Temperature measuring range (max.; min.) + 130.0 °C; - 30 °C
Temperature resolution 0.1 °C

FEATURES
Alarm settings Yes
Auto-off Yes
Automatic brightness control Yes
Automatic pressure compensation Yes
Calibration point indication Yes. with value
Calibration report Yes
Cell type 2 poles
DHS compatible Yes
Display Backlight coloured high-definition TFT
Electrode status indication Yes
GLP Yes
Inputs 3x BNC - RCA - Banana 4 mm Ref
ION calibration points 2...5
ISE measuring unit mg/l - g/l - mol/l
Memory 10.000 data
Multilanguage Eng - Ita - Deu - Esp - Fra - Cze
Online help Yes
Output Micro USB
Password Yes. 4 numerical scripts
pH alarm range Yes
Points of calibration Cond 1...4 automatic values / 1 custom value
Points of calibration ORP 1
Points of calibration pH 1...5 automatic values / 5 custom values
Selectable Cell constant 0.1 / 1 / 10
Stability criteria 3 levels
Standard approved Cond 84 μS - 147 μS - 1413 μS - 12.88 mS - 111.8 mS
Standard approved pH USA - NIST - DIN 19266
Temperature calibration Yes
Timer calibration due Yes
Ultrapure water compensation Yes

POWER SUPPLY
Power supply 4 x AA 1.5 V battery/USB Adaptor

DIMENSION AND WEIGHT
Dimension (LxWxH) 185 x 85 x 45 mm
Weight 455 g
More Information
Brand Giorgio Bormac s.r.l
Write Your Own Review
You're reviewing:XS ReVio Portable Multimeter with 201 T Electrode, 2301 T Conductivity Cell, polarographic DO Sensor and Accessories