Peltier-Cooled Incubator, 108L, Model IPP110eco

R 123,950.22
  • Chamber type: Peltier-cooled incubator (no compressor, no refrigerant)
  • Controller: SingleDISPLAY ControlCOCKPIT
  • Setting temperature range: 0°C to +70°C
  • Working temperature range: 0°C (min. 20 K below ambient) to +70°C (without light); +10°C to +40°C (with light, Option P1)
  • Setting accuracy (temperature): 0.1°C
  • Convection: Forced ventilation by Peltier fan
  • Internal volume: 108 L
  • Internal dimensions (W × H × D): 560 × 480 × 400 mm (usable depth less 32 mm for Peltier fan)
  • External dimensions (W × H × D): 745 × 864 × 555 mm (depth +56 mm door handle; +111 mm Peltier element)
  • Net weight: Approx. 63 kg
  • Electrical supply: 230 V or 115 V, 50/60 Hz; approx. 320 W
  • Installation: Fixed feet
  • Calibration document: Works calibration certificate included (+10°C, +25°C, +40°C)
  • Certifications: CE, EAC, VDE, cULus

Need a customised solution?

Optional accessories are available for purchase separately. If your order needs a customised configuration, our technical specialists will follow up with full details before your order is finalised. Contact us via the enquiry form or sales@lasec.com.

Installation, training and special delivery

Some products require installation, training, or special delivery (such as tail-lift trucks, extra labour, or hazardous material packaging). If your order needs this, we'll contact you with the additional cost before dispatch, so your final invoice may differ from the listed price.

Ordering from outside South Africa

Online ordering is currently limited to South African customers, but our full range is still available. Log an enquiry or email international@lasec.com and our international sales team will assist you through our traditional sales channels.

DISCLAIMER: All product images are for illustrative purposes only. Actual products may vary slightly in colours, controls, and visible features.
Availability:On Request
SKU
IMEMIPP110ECO
BrandMemmert

Product Overview

Memmert Peltier-Cooled Incubator, IPPeco Series

Refrigerant-free cooled incubation from 0 °C to +70 °C, across nine chamber sizes from 32 to 2 140 litres

The Memmert IPPeco is a range of Peltier-cooled incubators for microbiological and food science applications requiring precise temperature control both above and below room temperature. Operating without a compressor or refrigerant, the series covers a temperature range of 0 °C to +70 °C across nine chamber sizes from 32 to 2 140 litres.

Advanced Peltier Technology integrates fans directly into the Peltier elements, enabling rapid energy transfer and tight temperature homogeneity across the working chamber. The interior is sealed from the surroundings; condensation during cooling occurs on the Peltier element outside the working chamber rather than inside, reducing the risk of sample drying and protecting cultures from condensate exposure. The absence of a compressor means the IPPeco operates with low vibration and lower noise than equivalent refrigerant-cooled incubators, making it well suited to vibration-sensitive biological samples.

Each size is available as a base model with SingleDISPLAY ControlCOCKPIT, or as a "plus" variant with TwinDISPLAY, which supports temperature ramp programming and documentation via AtmoCONTROL software.

  • Temperature range: 0–+70 °C
  • Available volumes: 32–2 140 L
  • 9 sizes: 18 model variants
  • No compressor: Advanced Peltier Technology

Key Features

  • Advanced Peltier Technology: Peltier-based heating and cooling with no compressor and no refrigerant. Fans integrated into the Peltier elements support rapid energy transfer and optimum temperature distribution throughout the chamber.
  • Condensation-free working chamber: The interior is sealed from the surroundings. Condensation during cooling forms on the Peltier element outside the chamber, protecting samples from condensate and minimising drying risk.
  • Double doors, standard: Fully insulated stainless steel outer door and wide-area interior glass door on all models. Limits contamination and temperature fluctuation during access while allowing visual inspection of the chamber load.
  • Low vibration and low noise: The compressor-free design delivers lower vibration and quieter operation than refrigerant-cooled alternatives, an advantage for vibration-sensitive biological samples and shared laboratory environments.
  • SingleDISPLAY and TwinDISPLAY variants: Base models use SingleDISPLAY ControlCOCKPIT for straightforward operation. TwinDISPLAY ("plus") models add temperature ramp programming and full documentation via AtmoCONTROL software with integrated data logger.
  • Stainless steel construction: High-quality, corrosion-resistant stainless steel used almost exclusively for the working chamber and housing, supporting easy cleaning and long service life.
  • Precise temperature homogeneity: Fine Peltier control with minimal fluctuations across the full 0 °C to +70 °C working range ensures consistent conditions throughout the chamber, even when fully loaded.
  • Space-efficient footprint: The compressor-free design reduces the overall unit footprint compared to refrigerant-cooled incubators of equivalent capacity, freeing bench and floor space in the laboratory.

Applications

  • Microbiological analyses
  • Bacterial count determination
  • Cultivation above and below room temperature
  • Beer stability accelerated ageing tests
  • Shelf-life testing of dairy products
  • Food science research and quality assurance

Available Models

Model (SingleDISPLAY / TwinDISPLAY)Volume (L)Internal W × H × D (mm)
IPP30 / IPP30plus32400 × 320 × 250
IPP55 / IPP55plus53400 × 400 × 330
IPP110eco / IPP110ecoplus108560 × 480 × 400
IPP260eco / IPP260ecoplus256640 × 800 × 500
IPP410eco / IPP410ecoplus384640 × 1 200 × 500
IPP750eco / IPP750ecoplus7491 040 × 1 200 × 600
IPP1060eco / IPP1060ecoplus1 0601 040 × 1 200 × 850
IPP1400eco / IPP1400ecoplus1 3601 250 × 1 450 × 750
IPP2200eco / IPP2200ecoplus2 1401 972 × 1 450 × 750

The ACT® registered trademark is owned and controlled by My Green Lab Inc. More details at https://act.mygreenlab.org.

Temperature
Setting temperature range0 to +70 °C
Working temperature rangewith light: +10 to +40 °C
Working temperature rangewithout light: from 0 (at least 20 below ambient temperature) to +70°C
Setting accuracy temperature0.1 °C
Temperature sensor1 Pt100 sensor DIN class A in 4-wire-circuit
Control technology
Language settingGerman, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
ControlCOCKPITSingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display
TimerDigital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAITthe process time does not start until the set temperature is reached
Calibrationthree freely selectable temperature values
adjustable parameterstemperature (Celsius or Fahrenheit), programme time, time zones, summertime/wintertime
Ventilation
Convectionforced ventilation by Peltier fan
Communication
Documentationprogramme stored in case of power failure
ProgrammingAtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand).
Safety
Temperature controladjustable electronic overtemperature monitor and mechanical temperature limiter
Autodiagnostic systemfor fault analysis
Heating concept
Peltierenergy-saving Peltier heating-/cooling system integrated in the rear (heat pump principle)
Standard equipment
Works calibration certificatefor +10 °C, +25 °C and +40 °C
Doorfully insulated stainless steel door with 2-point locking (compression door lock)
Doorinner glass door
Internals2 stainless steel grid(s), electropolished
Stainless steel interior
DimensionsW(A) x H(B) x D(C): 560 x 480 x 400 mm (d less 32 mm for fan - Peltier)
Volume108 l
Max. number of internals5
Max. loading of chamber150 kg
Max. loading per internal20 kg
Textured stainless steel casing
DimensionsW(D) x H(E) x D(F): 745 x 864 x 555 mm (d +56mm door handle & +111mm Peltier element)
Housingrear zinc-plated steel
Electrical data
Voltage
Electrical load
230 V, 50/60 Hz
approx. 320 W
Voltage
Electrical load
115 V, 50/60 Hz
approx. 320 W
Ambient conditions
Set UpThe distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Ambient temperature16 °C to 40 °C
Humidity rhmax. 70 %, non-condensing
Altitude of installationmax. 2,000 m above sea level
Overvoltage categoryII
Pollution degree2
Packing/shipping data
Transport informationThe appliances must be transported upright
Customs tariff number8419 8998
WEEE-Reg.-No.DE 66812464
Dimensions approx incl. cartonw x h x d: 830 x 1050 x 800 mm
Net weightapprox. 63 kg
Gross weight cartonapprox. 86 kg

Frequently Asked Questions about the Peltier-Cooled Incubator, 108L, Model IPP110eco

Q: What is the temperature range of the Memmert IPP110eco?

A: The Memmert IPP110eco has a setting temperature range of 0°C to +70°C. Without the optional light module, its working range extends from 0°C to +70°C, with the lowest achievable temperature requiring a minimum difference of 20 K below ambient temperature.

Q: What is the capacity of the IPP110eco incubator?

A: The IPP110eco has an internal chamber volume of 108 litres. Its stainless-steel interior measures 560 × 480 × 400 mm (W × H × D), with the usable depth reduced by 32 mm for the Peltier fan.

Q: How does the Memmert IPP110eco heat and cool?

A: The IPP110eco uses an energy-saving Peltier heating and cooling system integrated into the rear of the incubator. It operates according to the heat-pump principle and does not require a conventional compressor or refrigerant.

Q: Does the IPP110eco use refrigerant?

A: No. The IPP110eco is a compressor-free and refrigerant-free Peltier-cooled incubator. This design also contributes to low vibration and quieter operation compared with conventional compressor-cooled systems.

Q: What controller is fitted to the IPP110eco?

A: The IPP110eco uses the SingleDISPLAY ControlCOCKPIT, an adaptive multifunctional digital PID microprocessor controller with a high-definition TFT colour display.

Q: What is the temperature setting accuracy of the IPP110eco?

A: Temperature can be set with a 0.1°C setting accuracy. Temperature measurement is provided by one Pt100 DIN Class A sensor in a 4-wire circuit.

Q: How is air circulated inside the IPP110eco?

A: The IPP110eco uses forced ventilation by a Peltier fan. Fans integrated with the Peltier system support efficient energy transfer and consistent temperature distribution throughout the chamber.

Q: How does the IPP110eco manage condensation during cooling?

A: The working chamber is sealed from the surroundings so that condensation generated during cooling forms on the Peltier element outside the working chamber. This helps protect cultures from direct condensate exposure and minimises the risk of samples drying out.

Q: Is the Memmert IPP110eco suitable for microbiology applications?

A: Yes. The IPP110eco is designed for applications including microbiological analyses, bacterial count determination and cultivation above and below room temperature. Its controlled temperature environment also supports food science and quality assurance workflows.

Q: What are typical applications for the IPP110eco?

A: Typical applications include microbiological analyses, bacterial count determination, cultivation above and below room temperature, beer stability accelerated ageing tests, shelf-life testing of dairy products, and food science research and quality assurance.

Q: Is the IPP110eco suitable for vibration-sensitive samples?

A: Yes. Its compressor-free Peltier design provides low-vibration operation compared with conventional refrigerant-cooled incubators, making it useful for biological samples and other applications where vibration should be minimised.

Q: Can the IPP110eco be fitted with an illumination module?

A: Yes. An optional light module, Option P1, can be used with this model. When operating with the light module, the specified working temperature range is +10°C to +40°C.

Q: What is the difference between the IPP110eco and IPP110ecoplus?

A: The IPP110eco is the base model with SingleDISPLAY ControlCOCKPIT. The IPP110ecoplus is the TwinDISPLAY “plus” version, adding temperature ramp programming and expanded documentation capabilities through AtmoCONTROL software with an integrated data logger.

Q: Does the IPP110eco support AtmoCONTROL software?

A: Yes. AtmoCONTROL software can be used for reading, managing and organising data logger information via the Ethernet interface. A temporary trial version can be downloaded, while a USB stick containing AtmoCONTROL is available as an accessory on demand.

Q: What timer functions are available on the IPP110eco?

A: The controller includes a digital backwards counter with a target time setting adjustable from 1 minute to 99 days. The SetpointWAIT function can prevent process time from starting until the selected temperature has been reached.

Q: Can the IPP110eco be calibrated at different temperatures?

A: Yes. Calibration can be performed at three freely selectable temperature values. A works calibration certificate covering +10°C, +25°C and +40°C is included as standard.

Q: What safety features does the IPP110eco include?

A: The incubator includes an adjustable electronic overtemperature monitor and a mechanical temperature limiter. An autodiagnostic system is also provided to support fault analysis.

Q: What doors are fitted to the IPP110eco?

A: The IPP110eco has a fully insulated stainless-steel outer door with two-point compression locking and an inner glass door. The inner glass door allows samples to be viewed while limiting disturbance to the chamber environment.

Q: How many shelves are supplied with the IPP110eco?

A: The incubator is supplied with two electropolished stainless-steel grids. The chamber can accommodate a maximum of five internals.

Q: What is the maximum loading capacity of the IPP110eco?

A: The chamber has a maximum total loading capacity of 150 kg. Each internal grid or shelf has a maximum permitted loading of 20 kg.

Q: What are the external dimensions of the IPP110eco?

A: The IPP110eco measures 745 × 864 × 555 mm (W × H × D). Installation planning should also allow an additional 56 mm of depth for the door handle and 111 mm for the rear Peltier element.

Q: How much does the Memmert IPP110eco weigh?

A: The IPP110eco has a net weight of approximately 63 kg. Its gross shipping weight, including the carton, is approximately 86 kg.

Q: How is the IPP110eco installed?

A: The IPP110eco is designed for installation on fixed feet. Adequate ventilation clearance must be maintained around the unit during installation.

Q: What electrical supply does the IPP110eco require?

A: The incubator is available for 230 V or 115 V, 50/60 Hz electrical supplies. Its approximate electrical load is 320 W.

Q: What installation clearances are required for the IPP110eco?

A: A minimum clearance of 15 cm behind the incubator, 20 cm above it and 5 cm at the sides from walls or adjacent equipment is required.

Q: What ambient conditions are suitable for the IPP110eco?

A: The specified ambient operating temperature is 16°C to 40°C, with relative humidity up to 70% and non-condensing. Installation altitude must not exceed 2 000 m above sea level. The unit is specified for overvoltage category II and pollution degree 2.

Q: How should the IPP110eco be transported?

A: The IPP110eco must be transported upright. Its approximate packaged dimensions are 830 × 1 050 × 800 mm, and its gross packaged weight is approximately 86 kg.

Q: What certifications does the Memmert IPP110eco have?

A: The IPP110eco carries CE, EAC, VDE and cULus certifications. The 110 L Peltier-cooled incubator is also listed in the My Green Lab ACT database.

Q: Does the Memmert IPP110eco have an ACT Ecolabel?

A: Yes. The 108 L IPP110eco is identified with the ACT Ecolabel. The ACT Environmental Impact Factor label provides information intended to help laboratories evaluate the environmental impact of laboratory products.

More Information
Model IPP110eco
Brand Memmert
Write Your Own Review
You're reviewing:Peltier-Cooled Incubator, 108L, Model IPP110eco
Your Rating