Optional accessories are available for purchase separately. If you require a customised solution, please contact our technical specialists by selecting the "Add to enquiry" button and using our enquiry form or at sales@lasec.com.
Installation, training and special delivery requirements, such as the need for tail-lift trucks and additional labour and installation for large equipment and hazardous material (Hazmat) packaging, are chargeable in addition to standard freight and will be quoted separately before dispatch.
Online ordering is currently limited to South African customers, but our full range is still available. If you are ordering from outside South Africa, please log an enquiry or email internationallabsales@lasec.com, and our international sales team will gladly assist you through our traditional sales channels.
The Memmert Incubator I Series is trusted worldwide in research laboratories, medical facilities, pharmaceutical development, and food testing laboratories. Designed for highly precise and stable temperature control, these incubators provide reliable conditions for microbiological incubation, cell culture applications, and temperature-sensitive testing procedures.
With a maximum temperature of +80 °C, the incubator is ideal for applications such as incubating living cultures at +37 °C. The precisely tuned heating system prevents temperature overshoot, ensuring delicate samples are heated gently and evenly.
The series is available in four model variants (IN, IF, INplus, IFplus) and eight chamber sizes, offering flexibility for a wide range of laboratory applications.
The Memmert Incubator I Series is available in four model variants and eight chamber sizes, allowing laboratories to select the ideal combination of airflow type and control system.
Variant | Air Circulation | Controller |
IN | Natural convection | SingleDISPLAY |
IF | Forced air circulation | SingleDISPLAY |
INplus | Natural convection | TwinDISPLAY |
IFplus | Forced air circulation | TwinDISPLAY |
Model | Chamber Volume |
IF30plus | 32 L |
IN30plus | 32 L |
IF30 | 32 L |
IN30 | 32 L |
IF55plus | 53 L |
IN55plus | 53 L |
IF55 | 53 L |
IN55 | 53 L |
IF75plus | 74 L |
IN75plus | 74 L |
IF75 | 74 L |
IN75 | 74 L |
IF110plus | 108 L |
IN110plus | 108 L |
IF110 | 108 L |
IN110 | 108 L |
IF160plus | 161 L |
IN160plus | 161 L |
IF160 | 161 L |
IN160 | 161 L |
IF260plus | 256 L |
IN260plus | 256 L |
IF260 | 256 L |
IN260 | 256 L |
IF450plus | 449 L |
IN450plus | 449 L |
IF450 | 449 L |
IN450 | 449 L |
IF750plus | 749 L |
IN750plus | 749 L |
IF750 | 749 L |
IN750 | 749 L |
| Temperature | |
|---|---|
| Setting temperature range | +20 to +80 °C |
| Working temperature range | at least 5 above ambient temperature to +80 °C |
| Setting accuracy temperature | 0.1 °C |
| Temperature sensor | 1 Pt100 sensor DIN class A in 4-wire-circuit |
| Control technology | |
| ControlCOCKPIT | SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display |
| Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
| Function SetpointWAIT | the process time does not start until the set temperature is reached |
| Calibration | three freely selectable temperature values |
| adjustable parameters | temperature (Celsius or Fahrenheit), air flap position, programme time, time zones, summertime/wintertime |
| Ventilation | |
| Convection | natural convection |
| Fresh air | Admixture of pre-heated fresh air by electronically adjustable air flap |
| Vent | vent connection with restrictor flap |
| Communication | |
| Documentation | programme stored in case of power failure |
| Programming | AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). |
| Safety | |
| Temperature control | adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature |
| Autodiagnostic system | for fault analysis |
| Standard equipment | |
| Works calibration certificate | incl. works calibration certificate for +37°C |
| Door | inner glass doors |
| Door | fully insulated stainless steel doors with2-point locking (compression door lock) |
| Internals | 2 stainless steel grid(s), electropolished |
| Stainless steel interior | |
| Interior | easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and optimised large-area heating on four sides |
| Volume | 749 l |
| Dimensions | W(A) x H(B) x D(C): 1040 x 1200 x 600 mm |
| Max. number of internals | 14 |
| Max. loading of chamber | 300 kg |
| Max. loading per internal | 30 kg |
| Textured stainless steel casing | |
| Dimensions | W(D) x H(E) x D(F): 1224 x 1720 x 784 mm (d +56mm door handle) |
| Installation | on lockable castors |
| Housing | rear zinc-plated steel |
| Electrical data | |
| Voltage Electrical load | 230 V, 50/60 Hz approx. 2000 W |
| Voltage Electrical load | 115 V, 50/60 Hz approx. 1800 W |
| Ambient conditions | |
| Set Up | The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. |
| Altitude of installation | max. 2,000 m above sea level |
| Ambient temperature | +5 °C to +40 °C |
| Humidity rh | max. 80 %, non-condensing |
| Overvoltage category | II |
| Pollution degree | 2 |
| Packing/shipping data | |
| Transport information | The appliances must be transported upright |
| Customs tariff number | 8419 8998 |
| Country of origin | Federal Republic of Germany |
| WEEE-Reg.-No. | DE 66812464 |
| Dimensions approx incl. carton | w x h x d: 1330 x 1910 x 1050 mm |
| Net weight | approx. 217 kg |
| Gross weight carton | approx. 288 kg |
Standard units are safety-approved and bear the test marks.
Q: What is the chamber volume of the IN750 incubator?
A: The IN750 incubator has a chamber volume of 749 L, providing ample space for microbiological incubation, cell culture work, and other laboratory temperature-controlled applications.
Q: What temperature range does the IN750 incubator support?
A: The incubator has a temperature setting range of +20 °C to +80 °C, with a working range from ambient temperature +5 °C up to +80 °C.
Q: What type of air circulation does the IN750 use?
A: The IN750 uses natural convection air circulation, which provides gentle and stable airflow ideal for sensitive biological samples and microbiological cultures.
Q: What is the temperature control accuracy of the incubator?
A: The incubator provides 0.1 °C temperature resolution, allowing precise control and stable incubation conditions.
Q: What type of temperature sensor is used?
A: The IN750 uses a Pt100 temperature sensor (DIN Class A) with a 4-wire circuit, ensuring accurate and reliable temperature measurement.
Q: What is the maximum load capacity of the incubator chamber?
A: The chamber supports a maximum total load of 300 kg, with each shelf capable of holding up to 30 kg.
Q: How many shelves can the incubator accommodate?
A: The IN750 can hold up to 14 shelves and is supplied with two stainless steel grid shelves as standard.
Q: What are the interior dimensions of the chamber?
A: The interior stainless steel chamber measures 1040 × 1200 × 600 mm (W × H × D).
Q: What are the exterior dimensions of the incubator?
A: The exterior dimensions are approximately 1224 × 1720 × 784 mm (W × H × D), excluding the door handle extension.
Q: What control system does the IN750 incubator use?
A: The incubator is equipped with the Memmert ControlCOCKPIT SingleDISPLAY controller, an adaptive digital PID microprocessor control system with a high-definition TFT colour display.
Q: Can the incubator run timed incubation programs?
A: Yes. The incubator includes a digital timer adjustable from 1 minute up to 99 days for controlled incubation processes.
Q: What safety features are included in the IN750 incubator?
A: Safety features include an adjustable electronic overtemperature monitor, a mechanical temperature limiter (TB) according to DIN 12880, and an integrated autodiagnostic system for fault detection.
Q: Does the incubator include a double door system?
A: Yes. The IN750 features a double door system consisting of an inner glass door for viewing samples and a fully insulated stainless steel outer door for stable temperature control.
Q: How does the incubator maintain uniform temperature distribution?
A: The chamber uses all-round heating integrated into the stainless steel interior walls combined with natural convection airflow to maintain consistent temperature distribution.
Q: What typical applications is the IN750 incubator used for?
A: Typical applications include microbiological incubation, cell culture research, pharmaceutical testing, food microbiology, and laboratory research.
Q: What is the power consumption of the IN750 incubator?
A: Power consumption is approximately 2000 W at 230 V or 1800 W at 115 V.
Q: What is the net weight of the IN750 incubator?
A: The incubator has a net weight of approximately 217 kg.
Q: What warranty is provided with the Memmert IN750 incubator?
A: The Memmert IN750 incubator includes a 3-year manufacturer warranty, ensuring reliable performance and long-term laboratory operation.