Optional accessories are available for purchase separately. If you require a customised solution, please contact our technical specialists by selecting the "Add to enquiry" button and using our enquiry form or at sales@lasec.com.
Installation, training and special delivery requirements, such as the need for tail-lift trucks and additional labour and installation for large equipment and hazardous material (Hazmat) packaging, are chargeable in addition to standard freight and will be quoted separately before dispatch.
Online ordering is currently limited to South African customers, but our full range is still available. If you are ordering from outside South Africa, please log an enquiry or email internationallabsales@lasec.com, and our international sales team will gladly assist you through our traditional sales channels.
The Memmert Incubator I Series is trusted worldwide in research laboratories, medical facilities, pharmaceutical development, and food testing laboratories. Designed for highly precise and stable temperature control, these incubators provide reliable conditions for microbiological incubation, cell culture applications, and temperature-sensitive testing procedures.
With a maximum temperature of +80 °C, the incubator is ideal for applications such as incubating living cultures at +37 °C. The precisely tuned heating system prevents temperature overshoot, ensuring delicate samples are heated gently and evenly.
The series is available in four model variants (IN, IF, INplus, IFplus) and eight chamber sizes, offering flexibility for a wide range of laboratory applications.
The Memmert Incubator I Series is available in four model variants and eight chamber sizes, allowing laboratories to select the ideal combination of airflow type and control system.
Variant | Air Circulation | Controller |
IN | Natural convection | SingleDISPLAY |
IF | Forced air circulation | SingleDISPLAY |
INplus | Natural convection | TwinDISPLAY |
IFplus | Forced air circulation | TwinDISPLAY |
Model | Chamber Volume |
IF30plus | 32 L |
IN30plus | 32 L |
IF30 | 32 L |
IN30 | 32 L |
IF55plus | 53 L |
IN55plus | 53 L |
IF55 | 53 L |
IN55 | 53 L |
IF75plus | 74 L |
IN75plus | 74 L |
IF75 | 74 L |
IN75 | 74 L |
IF110plus | 108 L |
IN110plus | 108 L |
IF110 | 108 L |
IN110 | 108 L |
IF160plus | 161 L |
IN160plus | 161 L |
IF160 | 161 L |
IN160 | 161 L |
IF260plus | 256 L |
IN260plus | 256 L |
IF260 | 256 L |
IN260 | 256 L |
IF450plus | 449 L |
IN450plus | 449 L |
IF450 | 449 L |
IN450 | 449 L |
IF750plus | 749 L |
IN750plus | 749 L |
IF750 | 749 L |
IN750 | 749 L |
| Temperature | |
|---|---|
| Setting temperature range | +20 to +80 °C |
| Working temperature range | at least 5 above ambient temperature to +80 °C |
| Setting accuracy temperature | 0.1 °C |
| Temperature sensor | 1 Pt100 sensor DIN class A in 4-wire-circuit |
| Control technology | |
| ControlCOCKPIT | SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display |
| Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
| Function SetpointWAIT | the process time does not start until the set temperature is reached |
| Calibration | three freely selectable temperature values |
| adjustable parameters | temperature (Celsius or Fahrenheit), air flap position, programme time, time zones, summertime/wintertime |
| Ventilation | |
| Convection | natural convection |
| Fresh air | Admixture of pre-heated fresh air by electronically adjustable air flap |
| Vent | vent connection with restrictor flap |
| Communication | |
| Documentation | programme stored in case of power failure |
| Programming | AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). |
| Safety | |
| Temperature control | adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature |
| Autodiagnostic system | for fault analysis |
| Standard equipment | |
| Works calibration certificate | incl. works calibration certificate for +37°C |
| Door | fully insulated stainless steel door with 2-point locking (compression door lock) |
| Door | inner glass door |
| Internals | 2 stainless steel grid(s), electropolished |
| Stainless steel interior | |
| Interior | easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides |
| Volume | 108 l |
| Dimensions | W(A) x H(B) x D(C): 560 x 480 x 400 mm |
| Max. number of internals | 5 |
| Max. loading of chamber | 175 kg |
| Max. loading per internal | 20 kg |
| Textured stainless steel casing | |
| Dimensions | W(D) x H(E) x D(F): 745 x 864 x 584 mm (d +56mm door handle) |
| Housing | rear zinc-plated steel |
| Electrical data | |
| Voltage Electrical load | 230 V, 50/60 Hz approx. 1400 W |
| Voltage Electrical load | 115 V, 50/60 Hz approx. 900 W |
| Ambient conditions | |
| Set Up | The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. |
| Altitude of installation | max. 2,000 m above sea level |
| Ambient temperature | +5 °C to +40 °C |
| Humidity rh | max. 80 %, non-condensing |
| Overvoltage category | II |
| Pollution degree | 2 |
| Packing/shipping data | |
| Transport information | The appliances must be transported upright |
| Customs tariff number | 8419 8998 |
| Country of origin | Federal Republic of Germany |
| WEEE-Reg.-No. | DE 66812464 |
| Dimensions approx incl. carton | w x h x d: 830 x 1050 x 800 mm |
| Net weight | approx. 76 kg |
| Gross weight carton | approx. 101 kg |
Q: What is the Memmert IN110 incubator used for?
A: The Memmert IN110 is used for microbiological incubation, cell culture (non-CO₂), food testing, pharmaceutical applications, and general laboratory research.
Q: What is the chamber capacity of the IN110 incubator?
A: The incubator has a 108-litre chamber capacity, providing sufficient space for routine laboratory applications.
Q: What temperature range does the IN110 support?
A: The unit offers a temperature setting range of +20 °C to +80 °C, with a working range from ambient +5 °C up to +80 °C.
Q: How accurate is the temperature control?
A: The incubator provides high precision with 0.1 °C setting accuracy, ensuring stable and reliable temperature conditions.
Q: What type of air circulation does the IN110 use?
A: The IN110 uses natural convection, providing gentle and uniform heating suitable for sensitive samples.
Q: Does the incubator prevent temperature overshoot?
A: Yes. The advanced PID control system prevents temperature overshoot, protecting delicate samples during incubation.
Q: What type of control interface does the IN110 have?
A: It features the ControlCOCKPIT interface with a TFT display, offering simple “Touch, Turn and Go” operation.
Q: Can the incubator run timed programs?
A: Yes. It includes a digital timer adjustable from 1 minute to 99 days for controlled incubation processes.
Q: What is the SetpointWAIT function?
A: The SetpointWAIT function ensures that the process timer only starts once the set temperature is reached, improving accuracy and repeatability.
Q: What materials are used in the construction of the incubator?
A: The interior is made from corrosion-resistant stainless steel with integrated all-round heating, ensuring durability and easy cleaning.
Q: Does the incubator have a double door system?
A: Yes. It includes a glass inner door for sample visibility and an insulated outer door to maintain stable temperature conditions.
Q: What is the maximum load capacity?
A: The chamber supports up to 175 kg total load, with a maximum of 20 kg per shelf.
Q: How many shelves can be used in the incubator?
A: The unit can accommodate up to 5 shelves and is supplied with 2 stainless steel grids as standard.
Q: Does the IN110 support data logging and connectivity?
A: Yes. It is compatible with AtmoCONTROL software and includes an Ethernet interface for data logging and control.
Q: What safety features are included?
A: Safety features include electronic overtemperature protection, mechanical temperature limiter (DIN 12880), and an integrated autodiagnostic system.
Q: What certifications does the IN110 incubator have?
A: The incubator is CE, VDE-GS, UL, and EAC certified and is supplied with a works calibration certificate at +37°C.
Q: What are the dimensions and weight of the unit?
A: The external dimensions are approximately 745 × 864 × 584 mm, and the unit weighs around 76 kg.
Q: What are the main advantages of the IN110 incubator?
A: Key advantages include precise temperature control, gentle natural convection heating, durable stainless steel construction, intuitive operation, and reliable performance for routine laboratory use.
| Brand | Memmert |
|---|