Memmert Climate and Humidity Chamber, HCP Series
Active humidity control for environmental simulation and accelerated service life testing
The Memmert HCP series comprises four climate chambers designed for applications that require precise, simultaneous control of temperature and relative humidity. Active humidity regulation across the full range of 20–95 % rh, combined with all-round surface heating on six sides including a heated inner glass door, produces a stable interior environment with minimised condensation risk and high homogeneity of both temperature and humidity.
Available in four sizes from 56 to 241 litres, the HCP series is suited to environmental simulation, accelerated service life testing, and 85/85 tests in accordance with IEC 60068-2-67 and IEC 60068-2-78. An aluminium thermal conductive layer supports uniform temperature distribution and serves as a heat accumulator during temporary power interruptions. Double doors are standard across all models, with a wide-area heated inner glass door that limits contamination risk and temperature fluctuation during access while providing a clear view of the chamber load.
All models are operated via the Memmert ControlCOCKPIT with TwinDISPLAY and the AtmoCONTROL software, which supports programming and documentation of temperature and humidity profiles. The SetpointWAIT function ensures that process runtimes begin only once the set temperature is reached, and three-fold overtemperature protection is standard. A rear panel feed-through port is included on all models. Battery-buffered ControlCOCKPIT and MobileALERT remote alarm notification (e-mail and SMS) are available as options.
Model | Volume (L) | Internal W × H × D (mm) |
HCP50 | 56 | 400 × 425 × 330 |
HCP105 | 107 | 560 × 480 × 400 |
HCP150 | 156 | 560 × 700 × 400 |
HCP240 | 241 | 600 × 810 × 500 |
| Temperature | |
|---|---|
| Working-temperature range | +7 above ambient temperature up to +90 °C |
| Setting temperature range | +18 to +90 °C |
| Setting accuracy temperature | 0.1 °C |
| Temperature sensor | 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error |
| Humidity | |
| Humidity Control | Active microprocessor control for humidifying and dehumidifying (20 – 95 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter |
| Setting range active humidity control | 20 to 95 % rh and rh-Off |
| Setting accuracy humidity | 0.5 % rh |
| Control technology | |
| ControlCOCKPIT | TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. |
| Language setting | German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese |
| adjustable parameters | temperature (Celsius or Fahrenheit), relative humidity, programme time, time zones, summertime/wintertime |
| Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
| Function SetpointWAIT | the process time does not start until the set temperature is reached |
| Calibration | three freely selectable values each, temperature and humidity |
| Communication | |
| Interface | Ethernet LAN, USB |
| Documentation | programme stored in case of power failure |
| Programming | AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |
| Safety | |
| AutoSAFETY | additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature |
| Autodiagnostic system | integral fault diagnostics for temperature and humidity control |
| Alarm | visual and acoustic |
| Heating concept | |
| 6 sides | large-area multi-function heating system on four sides with additional door and back heating to avoid condensation |
| Standard equipment | |
| Works calibration certificate | Works calibration certificate (measuring point chamber centre) at 60 °C with 75 % rh |
| Door | Additional heated inner glass door |
| Door | fully insulated stainless steel door with 2-point locking (compression door lock) |
| Entry port | Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back, centre left |
| Internals | 2 perforated stainless steel shelf/shelves |
| Standard accessories | Water tank including connection hose |
| Stainless steel interior | |
| Dimensions | w(A) x h(B) x d(C): 560 x 700 x 400 mm (d less 35 mm for fan) |
| Interior | W.-St. 1.4301 (ASTM 304) |
| Volume | 156 l |
| Max. number of internals | 10 |
| Max. loading of chamber | 120 kg |
| Max. loading per internal | 15 kg |
| Textured stainless steel casing | |
| Dimensions | w(D) x h(E) x d(F): 719 x 1070 x 591 mm (d +56mm door handle) |
| Electrical data | |
| Voltage Electrical load | 230 V, 50/60 Hz approx. 1800 W |
| Voltage Electrical load | 115 V, 50/60 Hz approx. 1800 W |
| Ambient conditions | |
| Ambient temperature | 10 °C to 30 °C |
| Set Up | The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. |
| Humidity rh | max. 70 %, non-condensing |
| Altitude of installation | max. 2,000 m above sea level |
| Overvoltage category | II |
| Pollution degree | 2 |
| Packing/shipping data | |
| Transport information | The appliances must be transported upright |
| Customs tariff number | 8419 8998 |
| Country of origin | Federal Republic of Germany |
| WEEE-Reg.-No. | DE 66812464 |
| Dimensions approx incl. carton | w x h x d: 800 x 1250 x 800 mm |
| Net weight | approx. 90 kg |
| Gross weight carton | approx. 116 kg |
| Brand | Memmert |
|---|