R 5,823.12
  • Model: P10
  • Range: MyPIPETMAN Select
  • Volume range: 1–10 µL
  • Nominal volume: 10 µL
  • Type: Manual air displacement, adjustable volume
  • Channels: 1
  • Ejector: Metal
  • Colour code: Red
  • Calibrated: Yes
  • Sterilisation: Fully autoclavable
  • Weight: 80 g (0.17 lb)
  • Dimensions (L × W × H): 24.53 × 6.77 × 3.8 cm
  • Compatible tips: PIPETMAN DIAMOND Tips D10, DL10, DF10ST, DFL10ST
  • Warranty: 3 years
  • Handle Personalisation available: MyPIPETMAN® Select pipettes can be supplied with printed handles on request, letting you dedicate an individual pipette to a specific liquid or workflow step. This supports contamination control and fits into a Lean Management approach on the bench.

Need a customised solution?

Optional accessories are available for purchase separately. If your order needs a customised configuration, our technical specialists will follow up with full details before your order is finalised. Contact us via the enquiry form or sales@lasec.com.

Installation, training and special delivery

Some products require installation, training, or special delivery (such as tail-lift trucks, extra labour, or hazardous material packaging). If your order needs this, we'll contact you with the additional cost before dispatch, so your final invoice may differ from the listed price.

Ordering from outside South Africa

Online ordering is currently limited to South African customers, but our full range is still available. Log an enquiry or email international@lasec.com and our international sales team will assist you through our traditional sales channels.

DISCLAIMER: All product images are for illustrative purposes only. Actual products may vary slightly in colours, controls, and visible features.
Availability:On Request
SKU
IGILFP10002S
BrandGilson

Product Overview

Manual air-displacement single-channel pipette

The MyPIPETMAN® Select P10 is a manual, air-displacement single-channel pipette covering a nominal volume range of 1–10 µL. Volume is adjusted using a push-button mechanism built around a volume-locking system, allowing the operator to choose between free volume setting, light ratchet setting, or a locked position for repeat pipetting.

The pipette is fully autoclavable and is supplied with a metal ejector and a curved, ergonomic push-button finger interface with a textured grip. An integrated ejection lever is intended to reduce the force needed to eject tips compared with direct-ejection designs.

An optional handle printing service is available, allowing individual pipettes to be identified and dedicated to a specific liquid or workflow step, intended to support contamination control and Lean Management practices in the laboratory.

Key Features

  • Trilock™ volume-locking system with three setting modes: free setting, light ratchet, and locked
  • Integrated ejection lever designed to reduce tip ejection force versus direct-ejection systems
  • Fully autoclavable construction
  • Ergonomic, textured push-button finger interface for extended use
  • Optional handle printing for pipette identification and workflow dedication
  • Colour-coded (red) for at-a-glance volume range identification
  • Calibrated at manufacture

Performance, Accuracy & Precision

Figures below are the manufacturer-stated systematic and random error values at three test volumes across the pipette's working range.

Test volume1 µL (10%)5 µL (50%)10 µL (100%)
Systematic error (µL)± 0.025± 0.075± 0.10
Systematic error (%)± 2.50± 1.50± 1.00
Random error (µL)≤ 0.012≤ 0.03≤ 0.04
Random error (%CV)≤ 1.20≤ 0.60≤ 0.40

Typical Applications and Workflows

(Bio)chemical reaction sampling, Bioassays (ELISA), Cell culture, DNA sequencing, DNA/RNA isolation & purification, Drug residues & metabolites extraction, Drugs of abuse — doping control, Automated dilution, Immuno affinity cleanup, Immunoprecipitation, Lipid & fatty acid profiling, Magnetic beads purification, MIC assay, Molecular genetics, NGSPCR/qPCR, Peptide desalting, Protein purification, Serial dilution, Solid phase extraction cleanup

Advantages

  • Single pipette design covers general molecular biology, immunoassay, and sample prep workflows without changing tools
  • Three volume-setting modes let the user match the setting method to the task at hand
  • Lower tip ejection force supported by the integrated lever design may reduce repetitive strain over high-throughput sessions
  • Autoclavable construction supports standard lab sterilisation protocols
Product Specifications
Applications & Workflows(Bio) Chemical Reaction Sampling, Bioassays (ELISA), Cell Culture, DNA Sequencing, DNA/RNA Isolation Purification, Drug Residues & Metabolites Extraction, Drugs of Abuse - Doping, General Automated Dilution, Immuno Affinity Cleanup, Immunoprecipitation, Lipid & Fatty Acids Profiling, Magnetic Beads Purification, MIC Assay, Molecular Genetics, NGS, PCR/qPCR, Peptide Desalting, Protein Purification, Serial Dilution, Solid Phase Extraction Cleanup
RangeMyPIPETMAN Select
ModelP10
Adjustable or Fixed VolumeAdjustable Volume
Nominal Volume10 µL
Systematic Error (μL)1 µL ± 0,025|5 µL ± 0,075|10 µL ± 0,10
Random Error (μL)1 µL ≤ 0,012|5 µL ≤ 0,03|10 µL ≤ 0,04
Systematic Error (%)10 % ± 2,50|50 % ± 1,50|100 % ± 1,00
Random Error (%CV)10 % ≤ 1,20|50 % ≤ 0,60|100 % ≤ 0,40
TypeManual Air Displacement
Volume Range1-10 µL
ConnectedNo
Number of Channels1
Volume10 µL
Ejector TypeMetal
CalibratedYes
Color CodeRed
Compatible TipsPIPETMAN DIAMOND Tips D10, DL10, DF10ST, DFL10ST
Finger StyleErgonomic, Curved, Push button
Grip TypeErgonomic, Textured
ProgrammabilityNo
Company ComplianceISO 9001, ISO 14001, ISO 13485
Product ComplianceISO 9001, ISO 14001, ISO 13485
Pack Information
Pack Size UnitEach
Packaging Dimensions32 x 11 x 4 cm
Packaging MaterialCarboard
StackableYes
Total Quantity1
Sustainability
DisposableReusable
MaterialPP, PA, PVDF, PBT, SS
Weights and Dimensions
Product Dimensions (L x W x H)24.53 x 6.77 x 3.8 cm
Product Length (Metric)24.53 cm
Product Weight (Metric)80 g
Product Weight (Imperial)0.17 lb
Warranty
Warranty3 years

Frequently Asked Questions about the MyPIPETMAN® Select P10, 1–10 µL, Metal Ejector

Q: What is the volume range of the MyPIPETMAN® Select P10?

A: The MyPIPETMAN® Select P10 has an adjustable volume range of 1–10 µL, making it suitable for precise low-volume pipetting applications such as PCR, qPCR, DNA sequencing, and molecular biology workflows.

Q: Is the MyPIPETMAN® Select P10 fully autoclavable?

A: Yes. The MyPIPETMAN® Select P10 is fully autoclavable, allowing convenient sterilisation for routine laboratory use and contamination control.

Q: What type of pipette is the MyPIPETMAN® Select P10?

A: The MyPIPETMAN® Select P10 is a manual, air-displacement, single-channel pipette with an adjustable volume range of 1–10 µL.

Q: How does the Trilock volume-locking system work?

A: The patented Trilock volume-locking system provides three operating modes: free volume setting for quick adjustment, light ratchet adjustment for precise volume selection, and a locked position to prevent accidental volume changes during pipetting.

Q: What are the benefits of the ergonomic design?

A: The MyPIPETMAN® Select P10 features a lightweight, well-balanced design, a textured ergonomic grip, a curved push button, and a patented integrated tip ejection system that reduces tip ejection force for improved comfort during extended use.

Q: Does the pipette have a metal tip ejector?

A: Yes. This model is fitted with a metal tip ejector, providing durability and reliable performance during routine laboratory use.

Q: Can the pipette be personalised?

A: Yes. The MyPIPETMAN® Select range offers optional handle printing, allowing laboratories to dedicate pipettes to specific liquids or workflows and support Lean laboratory management.

Q: Which pipette tips are compatible with the MyPIPETMAN® Select P10?

A: The pipette is compatible with PIPETMAN DIAMOND Tips D10, DL10, DF10ST, and DFL10ST.

Q: Is the MyPIPETMAN® Select P10 calibrated?

A: Yes. The pipette is supplied factory calibrated for accurate liquid handling.

Q: What accuracy and precision does the P10 provide?

A: At the nominal volume of 10 µL, the pipette has a systematic error of ±0.10 µL (±1.00%) and a random error of ≤0.04 µL (≤0.40% CV).

Q: How many channels does the MyPIPETMAN® Select P10 have?

A: The MyPIPETMAN® Select P10 is a single-channel pipette.

Q: Is the MyPIPETMAN® Select P10 programmable or connected?

A: No. This model is not programmable and does not include connectivity features.

Q: What applications is the MyPIPETMAN® Select P10 suitable for?

A: The pipette is suitable for a wide range of laboratory applications, including PCR/qPCR, DNA and RNA purification, DNA sequencing, ELISA, cell culture, molecular genetics, NGS, protein purification, serial dilutions, immunoprecipitation, and general liquid handling.

Q: What materials is the pipette manufactured from?

A: The MyPIPETMAN® Select P10 is manufactured from durable laboratory-grade materials including PP, PA, PVDF, PBT, and stainless steel (SS).

Q: What are the dimensions and weight of the pipette?

A: The pipette measures 24.53 × 6.77 × 3.8 cm and weighs approximately 80 g.

Q: What quality standards does the MyPIPETMAN® Select P10 comply with?

A: The pipette complies with ISO 9001, ISO 14001, and ISO 13485 quality management standards.

Q: Is the MyPIPETMAN® Select P10 reusable?

A: Yes. The MyPIPETMAN® Select P10 is a reusable laboratory pipette designed for long-term use.

Q: What warranty is provided with the pipette?

A: The MyPIPETMAN® Select P10 is supplied with a 3-year manufacturer’s warranty.