For research use only. Not for use in diagnostic procedures.
The chemagic™ 360 Instrument is a compact, flexible, and automated system for nucleic acid extraction across diverse sample materials and volumes, leveraging magnetic bead-based chemagic™ technology. Designed for laboratories requiring reliable high-throughput nucleic acid purification, it seamlessly integrates with NGS, MPLA, genotyping, PCR, and related downstream applications.
Wide Sample Volume Flexibility
Processes volumes from 50 µL to 18 mL, supporting diverse research needs from small cfDNA samples to large-volume blood extractions.
High Throughput and Efficiency
Supports rapid processing of large sample numbers, increasing laboratory productivity.
Extensive Kit Portfolio
Compatible with a broad range of chemagic™ kits for genomic DNA, cfDNA, total RNA, viral and bacterial nucleic acids across various sample types.
Cross-Contamination Prevention
Magnetic bead-based purification minimises cross-contamination and carry-over of inhibitors, ensuring reliable and clean extractions.
Versatile Sample Compatibility
Capable of processing different sample materials in a single run, including blood, swabs, plasma, and more.
Laboratory Workflow Integration
Features barcode reading for LIMS-compatible sample tracking and automated buffer filling, streamlining sample management.
User-Friendly, Intuitive Software
The chemagic™ software enables easy protocol setup, sample tracking, and generation of LIMS-compatible log files, simplifying laboratory operations.
Space-Efficient Benchtop Design
Compact footprint allows integration into various laboratory environments without compromising performance.
Patented Magnetic Bead Technology
Utilises Revvity’s patented M-PVA Magnetic Bead Technology for consistent, high-quality nucleic acid yields.
The chemagic™ 360 can be configured with three interchangeable rod heads to match throughput and sample volume requirements:
Configuration | Product Number | Samples per Run | Sample Volumes | Format | Processing Time |
---|---|---|---|---|---|
chemagic™ 360 12 Rod Head Set | CMG-371 | 1–12 | 0.5 mL – 18 mL | 50 mL tubes | ~55 min for 10 mL blood |
chemagic™ 360 24 Rod Head Set | CMG-376 | 1–24 | 200 µL – 10 mL | 24-well plates XL | ~55 min for 4 mL blood |
chemagic™ 360 96 Rod Head Set | CMG-370 | 1–96 | 10 µL – 1.5 mL | 96-well plates | ~55 min for 400 µL blood or ~31 min for 96 swabs |
Engineered for modern laboratories, the chemagic™ 360 Instrument allows you to focus on scientific discovery while it automates and streamlines nucleic acid extraction. With flexibility across applications such as human genetics, HLA typing, pathogen detection, and biobanking, it is an essential addition to high-throughput laboratories aiming to produce consistent, high-quality nucleic acid yields for downstream analyses.
“We are using the chemagic™ 360 for COVID-19 testing, running the 32-minute short protocol, allowing us to process ~4000 samples/day with two instruments. The instrument has consistently delivered quality, reliable data.”
— Department of Microbiology, Government of Rajasthan, S.M.S. Medical School, Jaipur
“The chemagic™ 360 has proven highly versatile for our nucleic acid extraction needs, and integrating the viral extraction and RT-PCR kits provided a seamless workflow with a trusted supplier.”
— Biopsense, Jyväskylä, Finland
Watch how researchers at Memorial Sloan Kettering Cancer Centre (NY, USA) and Sampled (NJ, USA) utilise the chemagic™ 360 in their workflows.
A: The chemagic™ 360 Instrument is a flexible, automated system designed for nucleic acid extraction from diverse sample materials such as blood, plasma, swabs, and more, using magnetic bead-based chemagic™ technology.
A: The instrument can handle sample volumes ranging from 50 µL up to 18 mL, making it suitable for a variety of research applications.
A: It measures 80.0 cm (W) × 80.0 cm (D) × 90.0 cm (H) and weighs approximately 140 kg.
A: Yes. It supports cfDNA, DNA, RNA, DNA/RNA isolation, and viral nucleic acid extractions.
A: No, the chemagic™ 360 is intended for research use only and is not for diagnostic procedures.
A: It employs magnetic bead-based purification methods that reduce the risk of cross-contamination and carry-over of inhibitors, ensuring clean and reliable nucleic acid extractions.
A: Typical processing times range around 55 minutes, varying slightly based on sample volume and type (e.g., ~55 min for 10 mL blood with the 12-rod head, ~31 min for 96 swabs with the 96-rod head).
A: Yes, it features barcode reading and generates LIMS-compatible log files for seamless laboratory information management system (LIMS) integration and efficient sample tracking.
A: The instrument uses Revvity’s patented M-PVA Magnetic Bead Technology, ensuring consistent and high-quality nucleic acid yields.
A: Yes. Its versatility allows it to process various sample types in a single run, including blood, swabs, plasma, and others.
A: Automated extraction improves efficiency, reduces manual errors, increases productivity, and supports consistent, high-quality nucleic acid isolation.
A: It is beneficial for applications such as next-generation sequencing (NGS), PCR, genotyping, pathogen detection, human genetics, biobanking, and molecular diagnostics research.
A: Yes. It includes user-friendly software enabling intuitive protocol setup, straightforward sample tracking, and simplified laboratory operation.
A: Users report increased laboratory productivity, enhanced workflow efficiency, reliable and high-quality data, reduced manual intervention, and seamless integration into existing workflows.
A: It offers interchangeable rod heads:
12 Rod Head Set: Processes 1–12 samples (0.5–18 mL each).
24 Rod Head Set: Processes 1–24 samples (200 µL–10 mL each).
96 Rod Head Set: Processes 1–96 samples (10 µL–1.5 mL each).
Brand | Revvity |
---|