STERIPLUS™ 80

STERIPLUS™ 80

Enquire for Price
  • On-site treatment solution for infectious risk waste

  • Integrated infectious waste pre-shredding and steam sterilisation system

  • Load Capacity (Volume): 80 L
  • Loading Chamber Useful Dimensions (w x d x h): 370 x 360 x 628 mm
  • Load Capacity (Containers): 1 x TESABOX 80 or 2 X TESABOX 40 or 4 X TESABOX 20
  • External Dimensions (w x d x h): 1550 x 1200 x 1800 mm
  • Net Weight: 1300 kg
Availability:On Request
SKU
ITESPF-0011
BrandTesalys

The Tesalys STERIPLUS™ 80 is the optimal solution for safe on-site inactivation of infectious waste. Its integrated TESASHRED™ system not only significantly reduces the waste's volume and weight but also ensures deep and thorough treatment.

Advantages of the STERIPLUS™ 80:

  • Fully automated: The STERIPLUS™ 80 is an easy-to-use, on-site processing solution.
  • Large capacity: The loading chamber has a capacity of 80 litres, i.e. 1 TESABOX 80 or 2 TESABOX 40 or 4 TESABOX 20.
  • Fully integrated system: The STERIPLUS™ 80 is a fully automated solution for pre-grinding and steam sterilisation of infectious wastes.

To avoid the costs and risks associated with biohazardous waste storage and transportation, especially for health care providers generating smaller volumes, the Tesalys STERIPLUS™ System has been developed with the following objectives:

  • User-friendly for waste generators.
  • Flexibility to be set up as close as possible to the waste source.
  • Compliance with timeframes for biohazardous waste generation and disposal.
  • Utilisation of advanced, easily validated technology.
  • Adaptability to the amount of waste being disposed of.
  • Ability to handle small, immediate waste flows.
  • Cost-effective investment.

The Tesalys STERIPLUS™ System is a disinfection pre-treatment solution for biohazardous waste, according to the French standard NF X30-503-1. It combines a steriliser (autoclave) with an integrated shredder. This system first shreds the waste and then undergoes an autoclave cycle using steam at 135°C (275°F). Post-treatment, the biohazardous waste is transformed into material akin to municipal solid waste, which can then be disposed of like standard industrial or household waste. Environmental consciousness has been at the forefront of Tesalys design considerations. Apart from treating the emissions and effluents produced by the equipment, the system is energy and water-efficient due to its heat-recovery mechanisms.

Technical Data
Loading Chamber Capacity80 L
Loading Chamber Useful Dimensions (wxdxh)370 x 360 x 628 mm
Loading Capacity (Containers)1 X TESABOX 80 or 2 X TESABOX 40 or 4 X TESABOX 20
Total Cycle Time (NF X30-503-1 Standard) (1)30 to 35 min
Total Cycle Time in Working Conditions (2)30 to 50 min.
Loading Capacity (kg/Cycle) 6.4 to 9.6 kg/cycle - Based on an average waste density of 0.08 to 0.12kg/L for Healthcare Waste
9.6 to 16 kg/cycle - Based on an average waste density of 0.12 to 0.2kg/L for Lab/Humid/Liquid Waste
Treatment Capacity (kg/h) (3) 8 to 12 kg/h - Based on an average waste density of 0.08 to 0.12kg/L for Healthcare Waste
12 to 20 kg/h - Based on an average waste density of 0.12 to 0.2kg/L for Lab/Humid/Liquid Waste
Max Quantity of Liquid Recommended Per Cycle (4)24 L
External Dimensions (wxdxh)1550 x 1200 x 1800 mm
Net Weight1300 kg
Loading ChamberStainless steel with PTFE coating
Treatment ChamberAISI 304L stainless steel
Steam GeneratorAISI 304L stainless steel (chamber) and Highly corrosion resistant Hastelloy®
Water SoftenerBuilt-in
Water Booster Pump and Air CompressorBuilt-in
Waster ShredderStructure: AISI 304L stainless steel and Blades: High-strength steel
PipingStainless steel/PTFE flexible hosing
ChassisPainted steel
BodyworkComposite material / Painted steel
Cycle Traceability - Through PrintoutBuilt-in
USB PortBuilt-in
Use Data
WATER
RequirementsSoftened water (4-8°TH)
Consumption15 liters / cycle
ELECTRICITY
Requirements380-400 V III N, 50Hz/60Hz, 20 kW
Consumption3 kW/h / cycle
DRAINø 32 mm internal (heat-resistant)
STEAM/COMPRESSED AIRProduced by the integrated steam generator and air compressor; no external connection required.

(1) 30-35 minutes for test loads as per the NF X30-503-1 standard.

(2) Cycle times may vary based on the type of materials, waste density, humidity, quantity of liquids, etc. For loads with high liquid content, the cycle time can be longer. Up to 50 minutes, depending on the waste density.

(3) Based on an average cycle time of 45 min. (40 min. of cycle + 5 min. unloading/loading time).

(4) The quantity of liquids allowed might vary depending on the application (urine bags, blood bags, food testing bags, etc.).

All the data given in this catalog is non-binding and given as a guide only. Treatment capacities, cycle times, and consumptions are given as mere examples and may vary depending on the type of waste, installation conditions, operator’s availability, and skills. Consumption is calculated on the basis of a standard cycle of the machine. For consumption with cooling of the drain and/or the virus + kit, please contact us.