Clean-Trace® ATP Hygiene Monitoring Luminometer, Model LM1

R 58,609.72
  • Brand: Clean-Trace®
  • Analyte: ATP
  • Result Type: Quantitative (Relative Light Units, RLU)
  • Reaction Chemistry: Luciferin/luciferase bioluminescence
  • Threshold Determination: Site-defined pass / caution / fail via on-site validation study
  • Power Source: Internal rechargeable battery; AC supply 100–240 V, 50/60 Hz
  • Display: 5.5 × 7.5 cm touch screen
  • Connectivity: USB 2.0 Mini-AB, wireless
  • Dimensions (L × W × H): 59.27 × 88.47 × 268.17 mm
  • Weight: 517.83 g
  • Operating Conditions: +5 to +40°C, 10–90% RH non-condensing, indoor use only
  • Approvals: AOAC PTM #041901
  • Compatible Test Devices (sold separately): Clean-Trace® Surface ATP UXL100; Clean-Trace® Water Plus – Total ATP AQT200; Clean-Trace® Water – Free ATP AQF100
- +

Need a customised solution?

Optional accessories are available for purchase separately. If your order needs a customised configuration, our technical specialists will follow up with full details before your order is finalised. Contact us via the enquiry form or sales@lasec.com.

Installation, training and special delivery

Some products require installation, training, or special delivery (such as tail-lift trucks, extra labour, or hazardous material packaging). If your order needs this, we'll contact you with the additional cost before dispatch, so your final invoice may differ from the listed price.

Ordering from outside South Africa

Online ordering is currently limited to South African customers, but our full range is still available. Log an enquiry or email international@lasec.com and our international sales team will assist you through our traditional sales channels.

DISCLAIMER: All product images are for illustrative purposes only. Actual products may vary slightly in colours, controls, and visible features.
Availability:In stock
SKU
ILSCLM1
BrandNeogen

Product Overview

The Clean-Trace® Luminometer LM1 is the handheld reader at the centre of Neogen's Clean-Trace® Hygiene Monitoring and Management System, alongside Clean-Trace® Tests and the Clean-Trace® Hygiene Management Software. The system detects adenosine triphosphate (ATP) on surfaces or in water samples as a measure of contamination, supporting hygiene verification and audit readiness in food and beverage manufacturing environments. ATP is present across animal and vegetable material, including food debris and living or dead microorganisms, making it a practical general indicator of residual soil or biological contamination.

Detection is based on ATP bioluminescence: the Clean-Trace® Tests use a luciferin/luciferase enzyme reaction to produce light in proportion to the ATP present in the sample. The LM1 measures the intensity of this light and displays the result in Relative Light Units (RLU) on its 5.5 × 7.5 cm touch screen. Each site establishes its own RLU pass, caution, and fail thresholds through a validation study on its own surfaces or water samples, so results are interpreted against site-specific criteria rather than a fixed universal scale.

Results transfer to the Clean-Trace® Hygiene Monitoring and Management Software over USB or wireless connection, where they can be tracked over time across sites, lines, and shifts. The software interface is available in 23 languages, supporting multilingual production teams. A fail result allows the test point to be re-cleaned and retested before production begins, and the accumulated results feed into the broader decision on whether to release a line for food or beverage production.

The LM1 is supplied as the luminometer and software package only. It is used together with Clean-Trace® Surface ATP UXL100 swabs, Clean-Trace® Water Plus – Total ATP AQT200, or Clean-Trace® Water – Free ATP AQF100 test devices, each sold separately, depending on the sample type being tested.

Key Features

  • 5 × 7.5 cm touch screen display for on-unit results and navigation
  • Ergonomic, one-handed design for rapid and repeatable swab testing
  • ATP bioluminescence detection via a luciferin/luciferase enzyme reaction, reported in Relative Light Units (RLU)
  • Site-specific pass, caution, and fail thresholds set through an on-site validation study
  • Internal rechargeable battery, charged via a 100–240 V AC power supply for use anywhere on the production floor
  • USB 2.0 Mini-AB and wireless data transfer to Clean-Trace® Hygiene Monitoring and Management Software
  • Software interface available in 23 languages
  • Compact, robust housing suited to manufacturing floor use

Intended Use

The LM1 is a battery-operated luminometer used for the objective, sensitive determination of Clean-Trace® ATP test results. Its power supply is used to charge the internal battery. The Clean-Trace® Hygiene Management Software handles the transfer, organisation, and storage of the data the tests generate.

The LM1, its power supply, and the Clean-Trace® Hygiene Management Software are intended for use only with Neogen-evaluated products and applications. The luminometer is not intended for use in potentially flammable or explosive environments. A sensitive result does not mean a surface or solution is sterile, and the system is not intended for diagnostic use in humans or animals. Lasec® recommends that the Clean-Trace® system be operated by technicians trained on Clean-Trace® ATP test methods, and that users confirm the applicable workplace regulations for their site. Using the product outside its specified conditions may impair the protection it provides.

Environmental Operating Conditions

Indoor use onlyConnect data connections only to a computer conforming to IEC/EN/UL/CSA 60950-1; keep the Luminometer away from liquids and high humidity when connected to a computer
Altitude3 000 m maximum
Operating temperature range+5 to +40 °C (+41 to +104 °F)
Relative humidity10–90 %, non-condensing
Storage temperature range−40 to +70 °C (−40 to +158 °F)
Overvoltage categoryII
Pollution degree2

Typical Applications

  • Verification of cleaning effectiveness on food contact and processing surfaces
  • Water hygiene monitoring, covering both total ATP and free ATP testing
  • Re-clean and retest of failed test points ahead of production start-up
  • Ongoing hygiene trend tracking and audit preparation in food and beverage manufacturing

Advantages

  • Rapid, quantitative RLU results to support real-time hygiene decisions
  • Site-specific pass, caution, and fail thresholds rather than a fixed universal scale
  • Centralised data management and trend reporting through companion software
  • Single system covering surface, total ATP water, and free ATP water testing

Certifications & Compliance

AOAC Performance Tested Method™ (PTM) #041901

Frequently Asked Questions about the Clean-Trace® ATP Hygiene Monitoring Luminometer, Model LM1

Q: What is the Clean-Trace® ATP Hygiene Monitoring Luminometer LM1?

A: The Clean-Trace® LM1 is a handheld ATP luminometer used within the Clean-Trace® Hygiene Monitoring and Management System. It measures ATP from compatible surface or water tests and reports quantitative results in Relative Light Units (RLU).

Q: What does the Clean-Trace® LM1 measure?

A: The LM1 measures adenosine triphosphate (ATP). ATP can be present in food debris and other animal or vegetable material, as well as living or dead microorganisms, making it a general indicator of residual biological contamination.

Q: How does the Clean-Trace® LM1 detect ATP?

A: Compatible Clean-Trace® tests use a luciferin/luciferase bioluminescence reaction. The reaction produces light in proportion to the ATP present, and the LM1 measures the intensity of that light.

Q: What units does the LM1 use to report results?

A: Results are reported quantitatively in Relative Light Units (RLU).

Q: Does the LM1 have fixed pass and fail limits?

A: No. Pass, caution and fail thresholds are site-specific and should be established through an on-site validation study using the facility’s own surfaces or water samples rather than relying on a universal RLU threshold.

Q: What happens when a test point receives a fail result?

A: A failed test point can be re-cleaned and retested before production begins. Results can also contribute to the broader decision on whether a production line is ready for food or beverage production.

Q: What type of display does the Clean-Trace® LM1 have?

A: The LM1 features a 5.5 × 7.5 cm touch screen for viewing results and navigating the instrument.

Q: Is the Clean-Trace® LM1 portable?

A: Yes. The LM1 is a handheld, battery-operated luminometer with an ergonomic design intended to support one-handed use during hygiene monitoring activities.

Q: How is the LM1 powered?

A: The LM1 contains an internal rechargeable battery. Its power supply is used to charge the battery and supports an AC input of 100–240 V, 50/60 Hz.

Q: What connectivity options does the LM1 provide?

A: The LM1 supports USB 2.0 Mini-AB and wireless connectivity for transferring results to the Clean-Trace® Hygiene Monitoring and Management Software.

Q: What does the Clean-Trace® Hygiene Monitoring and Management Software do?

A: The software supports the transfer, organisation and storage of hygiene monitoring data. Results can be tracked over time across different sites, production lines and shifts to support trend monitoring and audit preparation.

Q: Is the Clean-Trace® software available in multiple languages?

A: Yes. The supplied product information states that the software interface is available in 23 languages, supporting use by multilingual production teams.

Q: Which test devices are compatible with the Clean-Trace® LM1?

A: The LM1 is compatible with Clean-Trace® Surface ATP UXL100, Clean-Trace® Water Plus – Total ATP AQT200, and Clean-Trace® Water – Free ATP AQF100 test devices.

Q: Are ATP test devices included with the LM1?

A: No. The LM1 is supplied as the luminometer and software package. Compatible Clean-Trace® surface and water test devices are sold separately.

Q: Can the Clean-Trace® LM1 be used for surface hygiene monitoring?

A: Yes. When used with the compatible Clean-Trace® Surface ATP UXL100 test, the LM1 can support verification of cleaning effectiveness on food-contact and processing surfaces.

Q: Can the LM1 be used for water hygiene monitoring?

A: Yes. The system supports water hygiene monitoring using Clean-Trace® Water Plus – Total ATP AQT200 or Clean-Trace® Water – Free ATP AQF100, depending on the type of ATP measurement required.

Q: What are typical applications for the Clean-Trace® LM1?

A: Typical applications include verification of cleaning effectiveness, surface hygiene monitoring, total and free ATP water testing, re-clean and retest workflows, hygiene trend tracking and audit preparation in food and beverage manufacturing.

Q: Does an acceptable ATP result mean that a surface is sterile?

A: No. The supplied product information specifically notes that a sensitive result does not mean a surface or solution is sterile. Results should be interpreted according to the site’s validated hygiene monitoring procedures.

Q: Is the Clean-Trace® LM1 intended for human or animal diagnostic use?

A: No. The Clean-Trace® system is not intended for diagnostic use in humans or animals.

Q: Can the LM1 be used in potentially flammable or explosive environments?

A: No. The luminometer is not intended for use in potentially flammable or explosive environments.

Q: What are the operating temperature and humidity limits for the LM1?

A: The LM1 is specified for operation from +5°C to +40°C at 10–90% relative humidity, non-condensing. It is intended for indoor use only.

Q: What is the storage temperature range of the LM1?

A: The specified storage temperature range is −40°C to +70°C.

Q: What is the maximum operating altitude for the LM1?

A: The LM1 is specified for use at altitudes of up to 3 000 m.

Q: Are there special requirements when connecting the LM1 to a computer?

A: Yes. Data connections should only be made to a computer conforming to IEC/EN/UL/CSA 60950-1. The luminometer should also be kept away from liquids and high humidity while connected to a computer.

Q: What are the dimensions of the Clean-Trace® LM1?

A: The luminometer measures approximately 59.27 × 88.47 × 268.17 mm.

Q: How much does the Clean-Trace® LM1 weigh?

A: The LM1 weighs approximately 517.83 g, supporting portable use around production environments.

Q: Should operators receive training before using the Clean-Trace® system?

A: The supplied information recommends that the system be operated by technicians trained in Clean-Trace® ATP test methods. Users should also confirm the workplace regulations and validated procedures applicable to their site.

Q: What approval does the Clean-Trace® LM1 have?

A: The Clean-Trace® system carries AOAC Performance Tested Method (PTM) #041901 as stated in the supplied product information.

More Information
Model LM1
Brand Neogen
Write Your Own Review
You're reviewing:Clean-Trace® ATP Hygiene Monitoring Luminometer, Model LM1
Your Rating