  • Sensor Type: Dew Point
  • Accuracy: ± 0.003 aW at 25°C (± 1°C)
  • Measurement Time: Less than 5 minutes at equilibrium
  • Display: 7” Full-Colour Graphic Touchscreen
  • Communication: USB-A, USB-B, Wi-Fi®
  • Temperature Control: Programmable: 15–50°C
  • Compliance: ISO 18787:2017
  • Calibration: Single-point or multi-point calibration capability
Starter Kit Contents: Each Waterlab aWLife instrument includes:
  • 25 sample cups
  • 25 lids
  • Power cord
  • USB cable for external PC connection
  • Stylus for touchscreen interaction
  • USB flash drive (contains digital manual and for data export)
  • Printed manual
Availability:On Request
SKU
ISTGSQKY090882
Precision Instrument for Shelf-Life Determination in Food, Pharmaceutical, Cosmetic, and Herbal Industries
The aWLife Water Activity Meter is a high-performance analytical instrument designed for precise and rapid determination of water activity (aW), a critical parameter in assessing shelf life, microbial stability, and product quality. Entirely developed and manufactured in Italy by Steroglass, aWLife represents the state of the art in water activity measurement and has become an indispensable tool for quality control in the food, pharmaceutical, cosmetic, herbal, and pet food sectors.
Key Features and Benefits
Fast and Accurate Measurement
  • Measurement time: < 5 minutes at equilibrium
  • Accuracy: ± 0.003 aW at 25°C (± 1°C)
  • Ensures repeatable and reliable results across a wide range of sample types
Dew Point Sensor Technology
  • Utilises a dew point sensor to measure true free water activity (aW), not secondary or proxy parameters.
  • Measurement is based on the thermal equilibrium between the liquid water phase in the sample and the vapour phase in the headspace.
  • Complies with ISO 18787:2017, ensuring global regulatory acceptance.
Touchscreen Graphic Interface
  • Features a 7” colour touchscreen display for intuitive navigation and operation.
  • Allows direct interaction with functions, calibration settings, and data export options.
  • Compatible with USB and Wi-Fi, enabling easy integration with PCs and external printers.
  • Includes automatic data storage, sample identification, and operator tracking.
Precise Temperature Control
  • Thermostated sample chamber with a temperature range of 15°C to 50°C.
  • Programmable settings ensure consistent test conditions during shelf-life studies and stability testing.
Single or Multi-Point Calibration
  • Supports both single-point and multi-point calibration using standard references.
  • Multi-point calibration ensures precise adjustment of the calibration curve for improved measurement accuracy.
Sensor and Chamber Design
  • The sensor block features a front-opening chamber for easy sample placement and cleaning.
  • Integrated fan system ensures homogeneous temperature and humidity distribution.
  • Highly sealed chamber prevents environmental interference and cross-contamination.
Applications and Use Cases
The aWLife meter is designed to address a wide range of applications where water activity plays a critical role in shelf-life determination, regulatory compliance, and product development.
Suitable for:
  • Food Products (moisture-sensitive goods, dry snacks, dairy, meats)
  • Pharmaceutical Formulations (powders, capsules, tablets)
  • Cosmetic Products (creams, lotions, gels)
  • Herbal Preparations (extracts, essential oils)
  • Pet Food (wet and dry formulations)
Why Choose aWLife Water Activity Meter?
The aWLife Water Activity Meter delivers unmatched accuracy, operational efficiency, and data integrity, making it the most advanced aW analyser currently available on the market. With its dew point sensing technology, user-friendly touchscreen interface, and compliance with international standards, aWLife is the optimal solution for industries requiring precise shelf-life assessment and quality control.
Frequently Asked Questions
Q: What is the aWLife Water Activity Meter used for?
A: It measures water activity (aW) in food, pharmaceutical, cosmetic, herbal, and pet food products to assess shelf life, microbial stability, and product quality.
Q: What sensor technology does it use?
A: The aWLife uses a dew point sensor, providing accurate, direct measurement of free water activity.
Q: How accurate is the measurement?
A: It offers ± 0.003 aW accuracy at 25°C (±1°C).
Q: How fast does it deliver results?
A: The aWLife delivers results in less than 5 minutes at equilibrium.
Q: What is the temperature control range?
A: It features programmable control between 15°C and 50°C for consistent measurement conditions.
Q: Is it compliant with international standards?
A: Yes, it complies with ISO 18787:2017, ensuring global regulatory acceptance.
Q: What type of display does it have?
A: It includes a 7” full-colour graphic touchscreen for intuitive navigation and operation.
Q: How can data be exported?
A: Data export is supported via USB-A, USB-B, and Wi-Fi®, and a USB flash drive is included.
Q: What calibration options are available?
A: Both single-point and multi-point calibration are supported, enhancing measurement reliability.
Q: What industries benefit from this device?
A: The aWLife is ideal for food processing, pharmaceuticals, cosmetics, herbal product testing, and pet food industries.
Q: What’s included in the starter kit?
  • 25 sample cups & lids
  • Power cord
  • USB cable
  • Stylus
  • USB flash drive (with manual and export)
  • Printed manual
Contact Us
To request a demonstration or speak with an expert about how aWLife can support your analytical workflows, contact us at sales@lasec.com.
Technical Specifications
Activity Water
Measuring rangefrom 0.030 – 1.000 aW
Accuracy± 0.003 aW at 25°C
Repeatability (standard deviation)± 0.001 aW
CalibrationSelective Calibration at 7 points (0.150 – 0.250 – 0.500 – 0.760 – 0.920 – 0.984 – 1.000) for Steroglass and non-Steroglass unsaturated standards
Single point Calibration at any point settable by the user, for saturated standards at any value
Equilibrium/measurement times< 5 minutes
SensorDew point sensor required by ISO 18787:2017
Sensor block with front opening for easy sample insertion and cleaning. Equipped with a fan for uniform headspace, a high-seal chamber with a seal that guarantees very little environmental interference.
Display resolution± 0.0001 aW (4 decimal places)
SecurityAdmin management and up to 15 users via password (in compliance with CFR21 Part 11 - guarantee of data immutability)
SoftwareFor external PC in bidirectional Windows environment, Industry 4.0 compliant
External ProbesAccess hole in temperature check, block with certified external probes
Temperature
ThermostattingComplete sample thermostatting: at +25° ± 1°C (adjustable from +15°C to +50°C)
Real sample temperature reading with dedicated infrared sensor (also equipped with temperature indicator for the lid and the base of the reading block and cooled mirror temperature sensor).
Operating range at room temperature+5°C to +50°C
Digital resolution0.01°C
Accuracy± 0.2°C
Uncertainty± 0.2°C