PC 80 PRO Benchtop Multimeter without pH Electrode, with VPT 80-1 Conductivity Cell, Stirrer and Accessories

PC 80 PRO Benchtop Multimeter without pH Electrode, with VPT 80-1 Conductivity Cell, Stirrer and Accessories

R27,174.62

Measurement range

  • pH-2,000 ... 20,000 (0,001 pH); 
  • mV-2000 ... + 2000 (0.1 mV); 
  • Conductivity: 0.00 µS ... 1000.0 mS; 
  • Resistivity: 1 O ... 10 MW; 
  • Salinity: 0.01 ... 100.0 ppt; 
  • TDS: 0.1 mg / l ... 500.0 g / l; 
  • °C-20 ... 120.0 (0.1 ° C);

Resolution 0,1 / 0,01 / 0,001 pH - 0,01 μS

Backlit coloured high-definition graphic display.

Data logger auto and manual, up to 1000 savings in GLP

On line guide multilanguage

Alphanumeric password

Graphic calibration report

Without pH electrode; cable S7 / BNC, temperature probe NT 55, with cell conductivity VPT 80/1 glass Platinum 2-electrode (C = 1) with temperature probe integrated, support holders, magnetic stirrer with adjustable speed, buffers coloured, glasses for calibration with stirring bars, software for downloading data and power supply.

Availability:On Request
SKU
IBOR50104252

Description: Multiparameter pH, mV, ION, COND, TDS, Salinity, Resistivity, Microprocessor digital benchtop temperature, resolution ± 0.1 / 0.01 / 0.001 pH / 0.01 µS. Large, backlit color graphic display. Simultaneous vision pH / COND and Temperature. Manual or automatic temperature compensation with NT 55 probe. Manual and automatic data logger function. Memory / recall up to 1000 data with date/time according to GLP. Automatic calibration from 1 to 5 points for pH according to GLP with date and time. Selectable buffer NIST, USA, DIN, or user-definable (5 values). ISE calibration from 2 to 5 points. Calibration report and innovative graphic representation of the sensor conditions. Display of the buffers used for calibration and electrode status. Automatic and manual conductivity calibration with recognition of 4 standards (84; 1413 µS, 12.88, and 111 mS) from 1 to 4 points with the calculation of the different cell constants and a user-defined standard. Automatic scale change, automatic and manual temperature compensation (0 ... 100.0 ° C) with NT 55 probe. Reference temperature (15 ... 30 ° C), Linear temperature coefficient (0.00 ... 10.00%) and non-linear for ultra-pure water. Selectable cell buffer (C = 0.1 - 1-10.0). Display of the standards used for calibration. Intuitive management of parameters via icons. Multilingual menu. Enter company data, operator ID, sample ID, and sensor ID via an external keyboard (included). Alarm setting and display functions in analog format, "Latch-reading" and "Stability" with titration mode and time stability for ISE. Recalibration alarm, self-diagnosis messages. Alphanumeric password for calibration management and memory cancellation. 2 USB outputs for external keyboard connection (included) and PC. RS232 port for printer connection. Magnetic stirrer with independent control. Quick manual online. PC software is downloadable for free. IP54 keyboard.


TECHNICAL SPECIFICATIONS

REGULATIONS
Regulations CE

PERFORMANCE
Accuracy (Cond) ± 1% f.s.
Accuracy (pH) ± 0.02
Accuracy (Resistivity) ± 1% f.s.
Accuracy (Salinity) ± 1% f.s.
Accuracy (TDS) ± 1% f.s.
Accuracy (Temperature) ± 0.2 °C
Cond measuring range (max.; min.) 1000 mS; 0.00 μS
Cond resolution 0.01 / 0.1 / 1 μS/cm (automatic scale)
Ion measuring range (max.; min.) 19999 mg/l; 0.001 mg/l
ORP measuring range (max.; min.) + 2000; - 2000
ORP resolution 1 / 0.1 mV
pH measuring range (max.; min.) + 20.00; - 2.00
pH resolution 0.1 / 0.01 / 0.001
Reference temperature (max.; min.) + 30 °C; + 15 °C
Resistivity measuring range (max.; min.) 10.00 MOhm*cm; 1.00 Ohm*cm
Salinity measuring range (max.; min.) 100 ppt; 0.01 ppm
TDS Factor (max.; min.) 1.00; 0.40
TDS measuring range (max.; min.) 500 g/l; 0.1 mg/l
Temperature coefficient (max.; min.) 10.00 % / °C; 0.00 % / °C
Temperature compensation 0.0...100.0 °C
Temperature measuring range (max.; min.) + 120.0 °C; - 20.0 °C
Temperature resolution 0.1 °C
Working temperature (max.; min.) + 45 °C; 0 °C

FEATURES
Analog view Yes
Calibration report Yes. printable. For pH parameters also graph report
Cell type 2 poles
DHS compatible Yes
Display Backlight coloured high definition TFT
Electrode status indication Yes. with icon
GLP Yes
GLP calibration Yes
Inputs 2 x BNC - 2 x RCA - banana 4 mm
ION calibration points 2...5
ION measuring unit mg/l - g/l - mol/l
IP protection IP 54
Memory 1000 data
Multilanguage Eng - Ita - Deu - Esp - Fra - Cze
Online help Yes
Output USB - USB tipo B - RS232
Password Yes. 4 alphanumerical scripts
pH alarm range Yes
Points of calibration Cond 1...4
Points of calibration pH 1...5 automatic values / 1...5 user values
Printer connection Yes
Selectable Cell constant 0.1 / 1 / 10
Stability criteria 3 levels
Standard approved Cond 84 μS - 1413 μS - 12.88 mS - 111.8 mS / 1 user value
Standard approved pH USA - NIST - DIN 19266 - 5 custom values
Timer calibration due Yes
Ultrapure water compensation Yes

POWER SUPPLY
Power supply 100 - 240 V / 50 - 60 Hz

DIMENSION AND WEIGHT
Dimension (LxWxH) 324 x 185 x 56 mm
Weight 1255 g
More Information
Brand Giorgio Bormac s.r.l
Write Your Own Review
You're reviewing:PC 80 PRO Benchtop Multimeter without pH Electrode, with VPT 80-1 Conductivity Cell, Stirrer and Accessories
Your Rating