Online ordering is currently limited to South African customers, but our full range is still available. If you are ordering from outside South Africa, please log an enquiry or email internationallabsales@lasec.com, and our international sales team will gladly assist you through our traditional sales channels.
The ALP Smart Lab Clave CL-40L is a best-selling, high-performance top-loading laboratory autoclave designed for reliable sterilisation of laboratory instruments, liquids, and media. Manufactured with Japanese craftsmanship, it offers an excellent balance of performance, safety, and cost-efficiency.
Featuring a large Ø400 mm chamber, intuitive operation, and a one-action safety interlock lid, the CL-40L is ideal for laboratories requiring dependable sterilisation with straightforward operation. Multiple operating modes, extended timing control, and integrated safety systems make it suitable for a wide range of laboratory and research applications.
Note: Some options (e.g. floating sensor) must be specified at the time of order and cannot be retrofitted.
Q: What is the chamber capacity of the CL-40L autoclave?
A: The CL-40L autoclave has a chamber volume of 117 litres with internal dimensions of Ø400 × 820 mm, allowing sterilisation of large laboratory loads.
Q: What types of materials can be sterilised in the CL-40L?
A: The autoclave is suitable for sterilising laboratory instruments, glassware, culture media, liquids, and biological materials, making it ideal for microbiology and research laboratories.
Q: What is the temperature range of the CL-40L autoclave?
A: The sterilisation temperature range is 100 °C to 137 °C, with additional functions including dissolving (40 °C to 99 °C) and warming (40 °C to 60 °C).
Q: What is the maximum pressure of the autoclave?
A: The CL-40L operates at a maximum pressure of 0.250 MPa, ensuring effective sterilisation performance.
Q: How long can sterilisation cycles run?
A: The sterilisation time is adjustable from 0 minutes up to 48 hours, providing flexibility for different laboratory applications.
Q: What operating modes are available?
A: The CL-40L offers three main modes: Sterilisation, Sterilisation + Warming, and Dissolving + Warming, allowing versatile use depending on the application.
Q: Is the CL-40L easy to operate?
A: Yes. The autoclave features simple, user-friendly operation—users load samples, select a programme, and press START. A clear display shows process status and progress.
Q: What safety features are included in the CL-40L autoclave?
A: The autoclave includes multiple safety systems such as lid interlock, double safety interlock (mechanical and thermal), low water level protection, over-temperature and over-pressure protection, pressure safety valve, leakage breaker, and sensor fault detection.
Q: How does the lid safety system work?
A: The CL-40L features a one-action safety interlock lid that locks securely during operation and only opens when temperature and pressure return to safe levels.
Q: Does the autoclave include a steam cooling system?
A: Yes. The integrated steam cooling system condenses discharged steam into water droplets, reducing humidity and odours in the laboratory environment.
Q: What is included with the CL-40L autoclave?
A: The unit includes two stainless steel baskets with dimensions of Ø380 × 400 mm for efficient loading of samples.
Q: Can the autoclave handle large sample loads?
A: Yes. The large chamber can accommodate items such as up to 8 × 500 mL or 5 × 1000 mL Erlenmeyer flasks, depending on configuration.
Q: Are there optional accessories available?
A: Yes. Optional accessories include a floating temperature sensor, printer for cycle recording, rapid cooling fan, temperature recorder, and additional baskets or containers.
Q: Is the CL-40L suitable for regulated environments?
A: Yes. The autoclave supports IQ/OQ documentation (optional) and is suitable for use in GMP and GLP laboratory environments.
Q: What are the installation requirements?
A: The autoclave requires connection to a 220–240 V power supply (18–20 A) and must be installed by a qualified engineer. It is supplied without a plug.
Q: What are the external dimensions and weight of the unit?
A: The external dimensions are 620 × 720 × 1160 mm (W × D × H), and the unit weighs approximately 95 kg.
Q: What are the typical applications of the CL-40L autoclave?
A: Typical applications include sterilisation of culture media, laboratory glassware, microbiology work, pharmaceutical testing, and food or environmental analysis.
Q: What are the key advantages of the CL-40L autoclave?
A: Key advantages include a large-capacity chamber, high safety standards, flexible operation modes, easy operation, and reliable performance at a competitive cost.